Fixed site cluster
A group of units placed near a building or a yard that will stand for the length of the job. It suits a long project with one main work area and a stable crew.
Portable toilets sized to crew size and placed within reach of the work, for construction sites across El Paso and El Paso County.
Fastest: call (888) 351-0294. Or send this and we call you back.
Construction site portable toilets are sized to the crew, placed within a short reach of the work and serviced on a schedule that matches the job. The federal construction standard, 29 CFR 1926.51, ties the number of facilities to the size of the crew. A local provider confirms the count and placement for each site across El Paso County.
A job site is a workplace, and the toilet count is a legal requirement under the federal construction standard as well as a matter of decency. The standard, in 29 CFR 1926.51, sets the number of toilets against the number of workers, and the count rises as the crew grows. The table is the starting point for every site plan.
A toilet has to be within reach of the work to count in practice. The federal rules allow mobile crews to be served by facilities that are reached within a practical distance, and an OSHA interpretation treats a toilet a worker cannot reach in good time as a poor one. On a long El Paso subdivision or a road project, that means placing units near the work, not at the gate.
Keep the units clean and stocked for the whole job. A dirty toilet does not meet the standard's intent, and an OSHA interpretation notes that an unsanitary facility does not count toward the minimum, even though the standard does not require it to be spotless.
Do not place a unit on a slope, near an open excavation, under a crane swing or on a trench edge, and keep the service route clear of heavy equipment. Report a unit that is leaning or blocked to the site superintendent the same day.
Count the largest crew on the site at one time, including each trade, and note the shift pattern. The federal table is applied to the largest group, not the average day.
Set the count from 29 CFR 1926.51(c)(1), which scales the toilet seats and urinals to the number of workers. Mobile crews that travel to nearby facilities are treated under the standard's own exception.
Units are set near the work zones, with a firm, level pad and a route the service truck can drive. A unit at the far gate is not within reach of a crew working at the back of the lot.
The servicing is set from the crew size and the heat. Heat speeds up the fill of a holding tank, and providers commonly service more often in the summer months.
Keep the service tickets and the count on file, and remove the units once the crew has left the zone. The provider gives you the trip tickets for the waste.
29 CFR 1926.51(c)(1) sets a count that rises with the number of workers. For a crew of 20 or fewer one facility is the base case, and the table steps up above that, with one toilet seat and one urinal per 40 workers in the next tier and one per 50 at 200 workers and above.
The table is applied to the crew on the site, and the crew is counted across all trades who work in the same zone. The tiers are a starting point, and a site with a long shift or a hot day may need more. The figures are the minimum, not the target for a well-run job.
OSHA's interpretation dated 17 May 2006 says an unsanitary toilet does not count toward the minimum. A unit that is filthy or unstocked is not a facility the crew can use, so the servicing is part of the count.
A toilet a worker can reach in good time, which an OSHA interpretation treats as a practical test measured in minutes. Mobile crews may be served by facilities at a nearby location under the standard's exception. Place units near the active work zones rather than at the gate.
Distance is a matter of time, not only metres. A crew working on a far corner of a road project needs a unit close enough that a worker can go and come back within a short break. On a large lot, that often means two or three clusters rather than one central unit.
The 2010 ADA Standards set an accessible count for portable toilet clusters, and construction-site units used only by construction personnel can be exempt. A site where visitors, inspectors or the public use the units does not get that exemption. Confirm the use with the provider before the count is set.
Many sites have a mix of crew and visitors. An inspector or a delivery driver who needs a restroom counts as a visitor for this purpose. The provider and the site superintendent agree on the use before the cluster is set, so the count is right from the start.
A group of units placed near a building or a yard that will stand for the length of the job. It suits a long project with one main work area and a stable crew.
Units relocated as the work moves across a large site, such as a subdivision or a road corridor. The provider moves them on a set schedule so the crew is always within reach.
Units used only by the construction crew, for which the accessible-unit cluster count can be exempt. A visitor or a public user changes that answer, so the use is confirmed before the count is set.
El Paso's construction work spans the eastside subdivisions, the central remodels and the road corridors that cross the city. Each one moves the crew around the site in a different way, so the cluster plan changes with the job type.
The desert heat is the main construction factor. Crews working through a summer afternoon drink more and use the units more, and the units heat up quickly in full sun. Place them in shade where the site allows and plan the servicing around the afternoon.
Monsoon storms can flood the low ground on a site. Units placed in a wash bottom or a drainage low point can be moved by water, so the provider picks higher ground and checks the pads after every heavy storm.
If it's an emergency, call now. For non-urgent construction site portable toilets, send the form and we'll call you back.
Not sure if you're covered? Check your ZIP code.
Crew restrooms for industrial yards, interstate road work and border-zone sites across El Paso and El Paso County, placed for truck access.
A single standard portable toilet placed on a level pad for job sites, remodels and yard events across El Paso and El Paso County.
Multi-stall restroom trailers for large gatherings and long job sites across El Paso and El Paso County, placed on level, accessible ground.
OSHA's toilet table in 29 CFR 1926.51(c)(1) sets toilet numbers by crew size: one facility for 20 or fewer workers, then one seat and one urinal per 40 workers above that, and per 50 at 200 or more.
Use the federal table in 29 CFR 1926.51(c)(1), which scales the count to the crew. Count the largest crew at one time, and confirm the number with the provider for your site.
Close enough that a worker can reach it in good time. An OSHA interpretation treats this as a practical test. Place clusters at each active work zone rather than at the gate.
Units used only by construction personnel can be exempt from the accessible cluster count. A site where visitors or the public use the units is not exempt, so confirm the use with the provider.
The provider services them on a set schedule. Keep the service tickets on file for the job, and ask for the trip ticket for the waste.
Yes. Units can be relocated on a set schedule as the work moves across a large site, so the crew is always within reach.